Hunter PC-DM Decoder Module for PRO-C

Hunter
SKU:
HEPCDM
£202.46 (Inc. VAT)
£168.72 (Ex. VAT)
(No reviews yet)
Current Stock:
Adding to cart… The item has been added
PC-DM Decoder Module for Pro-C
  • The Pro-C controller is supplied with a base 4-station module. The Pro-C is also compatible with the EZ Decoder System (EZDS) for hybrid conventional and two-wire operations. Add a Pro-C Decoder Module (PC-DM) to enable control for up to 32 total stations. This system uses the same EZ-1 decoders used with ICC2 and HCC controllers. Combined with web-based management tools the EZDS greatly simplifies irrigation management.
  • Simple push-button programming of decoders without the need for serial numbers
  • Electrical output on two-wire path: 24 VAC, 50/60 Hz• Up to two standard 24VAC solenoids per EZ-1 decoder output
  • Two-wire paths allow for tee-splicing in different directions
  • EZ-1 Decoders are rated IP68, submersible
  • Reliable operation over 600m, depending on wire size
  • Up to 54-station capacity, plus master valve
  • No special wire or connectors required
  • Allows hybrid operations of conventional and decoder stations
  • Compatible with any direct-burial wire
  • The PC-DM can only be installed in the last two station output slots (similar to PCM-900 and PCM-1600 installation). The PC-DM will not physically fit or operate in any other station output slot.
  • IMPORTANT: While the addition of this module increases total station count to 32, the first 4 stations cannot be programmed as decoders and must be wired conventionally to the 4-station master module. This leaves stations 5–32 available for EZ decoder operation. This allows for hybrid conventional/decoder operation. If only EZ decoders are to be used, there are 28 total stations available, and the first station must be programmed as station 5.

*Please note: Only compatible with units manufactured from FEB 2020*

Features
  • Two-wire decoder system for Pro-C controllers
  • Up to 28-station capacity, plus master valve
  • Wire paths possible for over 1 km; see wiring table
  • No special grounding or surge arrestors required in-line
  • EZ-1 single-station decoders have status LED for positive diagnostics
  • P/MV can be activated by decoder or direct controller output
  • EZ-DM output module works in any controller module slot
EZDS Wiring Distances
International Wire Distance*
0.8mm² 267m
1mm² 333m
1.5mm² 500m
2.5mm² 833
4mm² 1333m
*Distances in the wiring table are calculated based on 50 Hz, with wire temperature of 50°C and a 10% safety factor

Click for Product Data Sheet