Heron MI-144 Irrigation Controller
Available in 16 Zones and expandable up to 144 Zones
Mi- Program SpecificationUp to 60 independent programs.
- Run up to 6 valves in parallel as standard
- Possibility to run up to 12 valves in parallel with additional output cards.
- Up to 64 automatic starts.
- Daily, weekly and variable period automatic starts.
- Automatic starts can be set to run on odd or even days.
- Valves can be individually named e.g. Lawn1, Bed1.
- Valves can be specified to run on a time or volume basis.
- Valves can be allocated to one of five water meters.
- An optimal flow can be entered for every valve.
- A minimum, maximum and pipe break flow rate can be specified for each water meter.
- Valve times can be set from a minimum of 1 second to 10 hours.
- Valves can be allocated to an irrigation group.
- Rainfall can be monitored over 1 to 4 days, irrigation programs can be reduced by 25%, 50%, 75% or 100%.
- Manually percentage adjust (0% to 250%) .
- Separate manual percentage adjust for programs and valve groups.
- Continual cycling of irrigation programs between specified time of day. Delay between cycles can be set from 1 minute to 9 hours.
- Manually start an individual program or valve.
- Manually start multiple programs.
- User can select which program to stop or manually advance if multiple programs are running.
- Pump pressurisation time can be set in minutes and seconds.
- Programs can be configured to start, stop, freeze or manually advance on a remote input.
- Up to 10 remote inputs can be connected.
- Programs can be allocated up to 5 pump starts or master valves.
- Valves can be defined as ‘special outputs’ to control external devices e.g. fill a pond, switch lighting.
- Valves can be defined for back flush use.
- Irrigation programs can be inhibited by wind speed or wind direction.
- Programs can be integrated with light, rain, humidity, temperature sensors.
- Irrigation can be controlled from a calculated evapotranspiration (ET) value.
- The ET value can be calculated using a variety of sensors depending upon the required accuracy.
- Programs can be attached to a dosing recipe.
Mi-144 Hardware Specification
- Compatible with any 24V AC solenoid valve.
- Option to operate DC valves.
- Output current 1.2amps (resistive) with electronic overload cut-out.
- Output current is measured which can be displayed for diagnostic purposes.
- Two pump starts.
- Three digital inputs.
- One socket to connect additional cards
- Two sockets for connecting additional output boxes.
- One data conector to connect to a PC or GSM mobile phone module.
- Designed to operate in an industrial environment. High electrical noise immunity, can withstand a 2.5KV spike.
- Battery backed up real tme clock. Real time clock immune to high electrical noise.
- All outputs protected against electrical surges exceeding ANSI C62 surge suppression standards.
- Extra large graphical display - 115mm x 80 mm.
- Up to 4 multi-wire cable drivers can be connected to one irrigation controller.
- Run up to 4 valves in parallel on one cable driver.
- Total output current of each multi-wire cable driver is 1.0A.
- 4 inputs as standard, start, stop, weather station and flow meter.
- Compatible with any 24V AC solenoid valve.
- Up to 9 flow meters can be connected. Real-time flow monitoring.
- Flow meter input can read to 0.1LPM.
- Up to 16 remote inputs available.
- Operate 96 valves with one additional add box, 144 valves with two additional add boxes.